  1.  
  2. LattisNet(R) 
  3. System 3000 Concentrators
  4.  
  5. Highlights 
  6.  
  7. *    Multiple bus architecture allows integration of five Ethernet, two 
  8.     Token Ring and three FDDI networks into a single platform
  9.  
  10. *    Modular design, along with a wide choice of modules, enables the
  11.     Mel 3000 to be customized to meet specific networking needs
  12.  
  13. *    Support for integrated Ethernet switching, bridging and routing
  14.     eliminates need for external equipment
  15.  
  16. *    Media flexibility provides support for unshielded twisted pair,
  17.     shielded twisted pair, coaxial and fiber optic Ethernet, shielded 
  18.     twisted pair and unshielded twisted pair Token Ring, and shielded 
  19.     twisted pair and fiber optic FDDI from a single platform
  20.  
  21. *    Supports full IEEE 802.3 Ethernet repeater functionality, enabling
  22.     support for greater distances and intercommunication between 
  23.     multiple media types
  24.  
  25. *    Supports full IEEE 802.5 Token Ring ring-in/ring-out and repeater
  26.     capabilities to create large single rings without bridging or 
  27.     routing
  28.  
  29. *    Implements full ANSI FDDI standard over three 100 Mb/s paths
  30.     (primary, secondary and local)
  31.  
  32. *    Optional SynOptics management capabilities deliver network
  33.     topology, per-port control and monitoring of detailed status, 
  34.     performance and diagnostic information through an object- oriented 
  35.     graphical user interface
  36.  
  37.  
  38.     The LattisNet System 3000 family of concentrators deliver a flexible
  39. platform for implementing and supporting a variety of large, complex physical
  40. star-topology networks over a building's structured cabling system.
  41.     System 3000 concentrators feature a multiple-bus backplane 
  42. architecture which enables them to simultaneously support a combination of 10 
  43. megabit per second (Mb/s) Ethernet, 4 Mb/s and 16 Mb/s Token Ring, and 100 
  44. Mb/s Fiber Distributed Data Interface (FDDI) networks.  Through a variety 
  45. Ethernet, Token Ring and FDDI connectivity, internetworking and network 
  46. management modules, network designers can create custom configurations that 
  47. meet their specific networking needs.
  48.  
  49. Model 3000 Premises Concentrator
  50.  
  51.     The Model 3000 Premises Concentrator is designed for large, high-
  52. density network environments, where it supports multiple independent network 
  53. segments operating over structured cabling configured in an active-star 
  54. topology.  Fully utilized, a single Model 3000 can simultaneously support five
  55. independent Ethernet segments, two Token Ring networks and three FDDI paths,
  56. delivering maximum flexibility for a wide variety of network topologies. 
  57.     The Model 3000 chassis offers 12 slots to hold any combination of 
  58. System 3000 modules supporting IEEE 802.3-compatible Ethernet over unshielded 
  59. twisted pair wire, shielded twisted pair wire, fiber optic cable or thin 
  60. coaxial cable; IEEE 802.5-compatible Token Ring over unshielded or shielded 
  61. twisted pair wire; and American National Standards Institute (ANSI) X3T9.5 
  62. FDDI over fiber optic cable and shielded twisted pair wire.
  63.     When configured in an Ethernet network with a retiming or network 
  64. management module, the concentrator provides full IEEE 802.3 repeater 
  65. functionality.  The concentrator can also accommodate LattisNet(R) Ethernet 
  66. Switching Engines(tm) as well as local and remote bridges and routers, delivering
  67. integrated internetworking solutions from a single platform.  
  68.     The Model 3000 also supports Sycs' LattisNet Manager(tm) for DOS 
  69. and the UNIX-based Optivity(tm) network management systems.  When configured with
  70. System 3000 Ethernet, Token Ring and/or FDDI network management modules, the 
  71. concentrator's dedicated network management interface bus ps the 
  72. management system with concentrator-, module- and port- level monitoring and 
  73. control capabilities.
  74.     The Model 3000 can be installed in two mounting arrangements:  on a 
  75. table top and in an EIA- standard 19-inch equipment rack, occupying 11 rack-
  76. mounting units.  Four different versions of the concentrator are available.
  77.  
  78. Multi-segment Ethernet
  79.  
  80.     The Model 3000N Premises Concentrator includes a chassis, a front-
  81. accessible modular fan tray, a front-accessible Model 3002 460-watt Power 
  82. Supply, and a backplane bus capable of supporting up to five independent, 
  83. manageable Ethernet segments.  The backplane also includes a dedicated network
  84. management interface bus and a power supply bus.
  85.  
  86. Multiple Ethernet/Token Ring Networks
  87.  
  88.     The Model 3000NT Premises Concentrator is identical to the Model 
  89. 3000N, with the addition of two Token Ring buses on the concentrator 
  90. backplane.  The Token Ring buses support two independent, manageable Token 
  91. Rings, each of which can operate at either 4 Mb/s or 16 Mb/s.  The Model 
  92. 3000NT can support up to seven separate networks - five Ethernet and two Token
  93. Ring - simultaneously.
  94.  
  95. Ethernet, Token Ring and FDDI
  96.  
  97.     The Model 3000S Premises Concentrator is identical to the Model 
  98. 3000NT, with the addition of an FDDI bus configured to support up to three 
  99. separate ring paths - primary, secondary or local - running at 100 Mb/s.  The 
  100. Model 3000S can be configured to simultaneously support any combination of 
  101. Ethernet, Token Ring and FDDI networks from a single platform.  The networks 
  102. can operate independently, or they can be logically connected via external
  103. bridges or routers to create a large, integrated Ethernet/Token Ring/FDDI
  104. system.
  105.  
  106. Redundant Power Supplies
  107.  
  108.     The Model 3000 Premises Concentrator can also be configured with 
  109. optional redundant power supplies.  The Model 3000SR is identical to the Model
  110. 3000S, with the addition of a redundant 460-watt power supply system designed 
  111. around the Model 3100R Summing Module and two Model 3002 power supplies.
  112.     The Model 3100R Summing Module resides in a designated slot between 
  113. the power supplies, where it manages power sharing within the concentrator.  
  114. This load-sharing capability enables both power supplies to provide current to
  115. the concentrator simultaneously.  In the event one power supply should fail,
  116. power is automatically shifted to the functioning source for uninterrupted
  117. service.  Both power supplies are individually capable of supporting a
  118. fully-configured System 3000 concentrator under worst-case circumstances.
  119.  
  120. Model 3030 Department Concentrator
  121.  
  122.     The Model 3030 Department Concentrator is a four-slot version of the
  123. Model 3000, designed for medium-density departmental networks.  Like the Model
  124. 3000, the Model 3030 accommodates any combination of System 3000 host,
  125. network management or internetworking modules supporting Ethernet and Token
  126. Ring.
  127.     In networks configured with SynOptics' network management, the Model
  128. 3030's dedicated network management interface bus provides the management 
  129. system with concentrator-, module- and port-level monitoring and control
  130. capabilities.  When configured in an Ethernet network with a retiming or
  131. network management module, the concentrator provides full IEEE 802.3 repeater
  132. functionality.
  133.     The Model 3030 offers several mounting arrangements.  It includes 
  134. brackets for installation in an EIA-standard 19-inch rack, where the Model 
  135. 3030 occupies three rack-mounting units.  The Model 3030 can also be wall-
  136. mounted with the appropriate brackets or set on a table top. 
  137.     Front panel LED status indicators on the Model 3030 report AC and DC
  138. power and fan failures to simplify troubleshooting and fault determination.  
  139. The easily-removable back panel holds the power supply and fan, providing a 
  140. single assembly for rapid replacement.
  141.  
  142. Ethernet Only
  143.  
  144.     The Model 3030-01 includes a chassis, an easily-accessible power 
  145. supply/fan unit, and a backplane with Ethernet, network management interface 
  146. and power supply buses.
  147.  
  148. Ethernet/Token Ring 
  149.  
  150.     The Model 3030-04 is identical to the Model 3030-01 and includes two
  151. Token Ring buses on the concentrator backplane.  The Token Ring buses support 
  152. two independent Token Rings, each of which can operate at either 4 Mb/s or 16 
  153. Mb/s.  The Model 3030-04 can support three networks - one Ethernet and two 
  154. Token Ring - simultaneously.
  155.  
  156.  
  157. System 3000 Concentrators 
  158.  
  159. Specifications 
  160.  
  161. Network Protocols 
  162.     Ethernet:  10 Mb/s Manchester encoded IEEE 802.3 
  163.     Token Ring:  4 Mb/s or 16 Mb/s differential Manchester encoding 
  164.        IEEE 802.5 (Model 3000NT and Model 3000S) 
  165.     FDDI:  100 Mb/s with 4B/5B coding over three paths (primary, 
  166.        secondary and local) (Model 3000S) 
  167.  
  168. Standards Support
  169.     IEEE AUI (for connections via 10BASE5)
  170.     IEEE 802.3 10BASE-T
  171.     IEEE 802.3 10BASE2
  172.     IEEE 802.3 FOIRL
  173.     IEEE 802.5 Token Ring
  174.     ANSI FDDI X3T9.5 FDDI
  175.     ISO 9314-1 FDDI Physical Protocol (PHY) standard
  176.     ISO 9314-3 FDDI Physical Medium Dependent (PMD) standard 
  177.  
  178. Physical Dimensions
  179.     Model 3000 Concentrator:
  180.     (H) 19.2 in x (W) 19 in x (D) 12 in (includes rack mount flanges)
  181.     (H) 48.8 cm x (W) 48.3 cm x (D) 30.5 cm (includes rack mount
  182.        flanges) 
  183.     Model 3030 Concentrator:
  184.     (H) 5.2 in x (W) 19 in x (D) 15 in
  185.     (H) 13.2 cm x (W) 48.3 cm x (D) 38.1 cm     
  186.  
  187. Environmental Specifications
  188.     Operating temperature:  5*C to 40*C
  189.     Operating humidity:  85% max relative humidity, non-condensing
  190.     Operating altitude:  10,000 ft (3,048 m)
  191.     Storage temperature:  -25*C to 70*C
  192.     Storage humidity:  95% max relative humidity, non-condensing
  193.     Free fall/drop:  ISO 4180-2, NSTA 1A
  194.     Vibration:  IEC 68-2-6/34
  195.     Stock/bump:  IEC 68-2-27/29
  196.     Thermal rating:
  197.        Model 3000:  460 watts (1,600 Btu/hr) max (fully loaded); 62 
  198.         watts (210 Btu/hr) min (empty)
  199.        Model 3030:  150 watts (510 Btu/hr) max (fully loaded); 15 watts
  200.         (50 Btu/hr) min (empty) 
  201.  
  202. Weight 
  203.     Model 3000:
  204.        Chassis assembly, without power supply:  33.3 lbs (15 kg)
  205.        Power supply:  10.2 lbs (4.6 kg)
  206.        Fully loaded (approximate):  75 lbs (34 kg)
  207.        Shipping weight (approximate):  60 lbs (27 kg) 
  208.     Model 3030:
  209.        Chassis:  17.7 lbs (8 kg)
  210.        Fully loaded (approximate):  28 lbs (13 kg)
  211.        Shipping weight (approximate):  30 lbs (14 kg) 
  212.  
  213. Safety
  214.     UL listed (UL 1950) 
  215.     CSA certified (CSA 22.2 #950) 
  216.     TUV licensed (EN 60 950) 
  217.  
  218. Electromagnetic Emissions
  219.     Meets FCC Part 15, Subpart B, Class A
  220.     Meets EN 55 022 (CISPR 22: 1985), Class A or B
  221.     Meets General License VDE 0871, Class B (AmtsblVfg 243/1991, 
  222.        46/1992)
  223.     Meets VCCI Class 1 ITE
  224.     (Refer to individual reference sheets for additional information)
  225.  
  226. Electromagnetic Susceptibility
  227.     Electrostatic discharge (ESD):  IEC 801-2, Level 2/4
  228.     Radiated electromagnetic field:  IEC 801-2, Level 2
  229.     Electrical fast transient/burst:  IEC 801-4, Level 2/3
  230.     Electrical surge:  IEC 801-5, Level 1/3
  231.     (Refer to individual reference sheets for additional information)
  232.  
  233.  
  234. Model 3002 Power Supply 
  235.  
  236. Specifications 
  237.  
  238. Features
  239.     Slide mounted modular power supply
  240.     AC cable supplied for standard U.S. outlets
  241.     AC power-on lighted switch and DC power-good LED
  242.     AC input voltage selection on front panel
  243.     Protection:
  244.     *    Overvoltage protected outputs
  245.     *    Short circuit protection on outputs
  246.     *    Thermal shutdown on overheating 
  247.  
  248. Physical Dimensions
  249.     (H) 15 in x (W) 2.4 in x (D) 10.6 in
  250.     (H) 38 cm x (W) 6.2 cm x (D) 26.9 cm 
  251.  
  252. Weight
  253.     10.2 lbs (4.6 kg) 
  254.  
  255. Input Connector
  256.     Meets IEC and CEE-22 specifications 
  257.  
  258. Safety
  259.     UL Recognized, CSA Certified, TUV Licensed
  260.     UL listed (UL 1950) 
  261.     CSA certified (CSA 22.2 #950) 
  262.     TUV licensed (EN 60 950) 
  263.  
  264. Electromagnetic Emissions
  265.     Meets FCC Part 15, Subpart B, Class A
  266.     Meets EN 55 022 (CISPR 22: 1985), Class A or B
  267.     Meets General License VDE 0871, Class B (AmtsblVfg 243/1991,
  268.        46/1992)
  269.     Meets VCCI Class 1 ITE
  270.     (Refer to individual reference sheets for additional information)
  271.  
  272. Electromagnetic Susceptibility
  273.     Electrostatic discharge (ESD):  IEC 801-2, Level 2/4
  274.     Radiated electromagnetic field:  IEC 801-2, Level 2
  275.     Electrical fast transient/burst:  IEC 801-4, Level 2/3
  276.     Electrical surge:  IEC 801-5, Level 1/3
  277.     (Refer to individual reference sheets for additional information)
  278.  
  279. AC Characteristics 
  280.     AC line frequency:  47-63 Hz 
  281.     VAC input requirement:  90-132 VAC (110 VAC operation); 180-265 
  282.        VAC (220 VAC operation) 
  283.     AC volt amperes rating:  1,200 VA max 
  284.     Current rating:  8 amps (110 VAC operation); 4.2 amps (220 VAC 
  285.        operation)
  286.  
  287.  
  288.  
  289.  
  290. Model 3100R Summing Module Specifications 
  291. (for Model 3000SR Redundant Power Supply System) 
  292.  
  293. Electrical Specifications
  294.     Power consumption:  25W (+5V), 7W (+12V)
  295.     Thermal rating:  109 Btu/hr maximum 
  296.  
  297. Physical Dimensions
  298.     (H) 15 in x (W) 1.2 in x (D) 10.6 in
  299.     (H) 38 cm x (W) 3.1 cm x (D) 26.9 cm 
  300.  
  301. Weight
  302.     3 lbs (1.4 kg) 
  303.  
  304. Environmental Specifications
  305.     Operating temperature:  5*C to 40*C
  306.     Operating humidity:  85% max relative humidity, non-condensing
  307.     Operating altitude:  10,000 ft (3,048 m)
  308.     Storage temperature:  -25*C to 70*C
  309.     Storage humidity:  95% max relative humidity, non-condensing
  310.     Free fall/drop:  ISO 4180-2, NSTA 1A
  311.     Vibration:  IEC 68-2-6/34
  312.     Stock/bump:  IEC 68-2-27/29 
  313.  
  314. Electromagnetic Emissions
  315.     Meets FCC Part 15, Subpart B, Class A
  316.     Meets EN 55 022 (CISPR 22: 1985), Class A or B
  317.     Meets General License VDE 0871, Class B (AmtsblVfg 243/1991,
  318.        46/1992)
  319.     Meets VCCI Class 1 ITE
  320.     (Refer to individual reference sheets for additional information)
  321.  
  322. Electromagnetic Susceptibility
  323.     Electrostatic discharge (ESD):  IEC 801-2, Level 2/4
  324.     Radiated electromagnetic field:  IEC 801-2, Level 2
  325.     Electrical fast transient/burst:  IEC 801-4, Level 2/3
  326.     Electrical surge:  IEC 801-5, Level 1/3
  327.     (Refer to individual reference sheets for additional information)
  328.  
  329.  
  330. Model 3030 Power Supply 
  331.  
  332. Specifications 
  333.  
  334. Power Supply Characteristics
  335.     AC cable supplied for standard U.S. outlets
  336.     AC power-on lighted switch and DC power-good LED
  337.     Protection:
  338.     *    Overvoltage protected outputs
  339.     *    Short circuit protection on outputs 
  340.  
  341. Input Connector
  342.     Meets IEC and CEE-22 specifications 
  343.  
  344. AC Characteristics 
  345.     AC line frequency:  47-63 Hz 
  346.     VAC input requirement:  90-250 VAC 
  347.     AC volt amperes rating:  300 VA max 
  348.     Current rating:  3.0 amps nominal at 110 volts; 1.5 amps nominal 
  349.        at 220 volts
  350.  
  351. Corporate Headquarters 
  352. SynOptics Communications, Inc. 
  353. 4401 Great America Parkway 
  354. Santa Clara, CA  95054 
  355. Phone:  (408) 988-2400 
  356. Fax:    (408) 988-5525
  357.  
  358. System 3000, LattisNet Manager, Optivity and Expanded View are trademarks and
  359. LattisNet and SynOptics Communications are registered trademarks of SynOptics
  360. Communications, Inc.  Other brand and product names are  registered
  361. trademarks or trademarks of their respective holders.
  362.     
  363. P/N DA505-200US-C
  364.  
  365.